int YSize)
Function: This function sets the tablet so that the LCD display will only show
ink in a restricted area when data is input with a pen in
LCDCaptureMode = 2 and LCDCaptureMode = 3 inking modes.
Returning the tablet to the default state (using LCDCaptureMode = 1
for example) will reset these values.
Arguments: Integers:
XPos Location in LCD coordinates (upper left - 0,0).
YPos Location in LCD coordinates (upper left - 0,0).
XSize XSize in LCD pixels.
YSize YSize in LCD pixels.
Return Value: Bool TRUE if a checksum is received and verified.
FALSE if no or an incorrect checksum is received
from the tablet.
Remarks: Do not send a command with XSize or YSize = 0.